Honeywell, Lennox, and Davies - Opinion Time!

Winter has arrived, the furnace is in, the house is warm, and Katherine is very happy! Now it's time to give my blatantly honest and unbiased opinion on the furnace, the thermostat, and the company that installed it all.

Honeywell Prestige THX900 Touch Screen Thermostat
(Click Here For Information - New Window Will Open)

Simply Phenomenal! This unit has power supplied from the furnace, so no batteries to replace, ever! It offers the homeowner a level of control that simply cannot be matched by any setback thermostat you can buy at a retailer such as Canadian Tire (including other Honeywell thermostats). It offers complete and ridiculously simple end user control over setback programming, overrides, vacation programs, furnace cycle rates, and many other facets of the furnace operation. As an example, the old setback thermostat permitted me to override the current program until the new program kicked in. This new thermostat allows me to override the current program until either the next program kicks in, or anytime before the next program, or anytime through the next program. around $500 (plus HST) as a complete system (thermostat, remote, outdoor air sensor) from an HVAC supplier, installed.

Lennox G61MPV Two Stage High Efficiency Furnace
(Click Here For Information - New Window Will Open)

Quietly Impressive: There are two reasons to drop four grand on a great furnace: Two stage burners, and an electronically commutated fan blower motor. When the furnace is called on for heat, the first stage fires up delivering 60,000 BTU, and is then monitored. If heat demand is being met, the first stage only continues to burn. When demand is not being met, the second stage fires, and the full 90,000 BTU's comes on line. When the call for morning and evening heat comes, the furnace typically moves to full two stage heating, as it is pulling the house up 5 degrees celsius. Once the house is at the set temperature, only the first stage typically fires to maintain it. The blower motor is very quiet compared to the old Carrier with AC blower. With the old furnace you could always tell it was running anywhere in the home, but with the new Lennox you have to be in the dining room or front foyer to hear it, otherwise you would not know it is running. Operating noise appears to have been cut in half. $3900 (plus HST, less varous rebates) for a straightforward installation by Dave Davies, available through any Lennox dealer.

Dave Davies Air Conditioning, Heating and Refrigeration
(Click Here For Information - New Window Will Open)

Absolutely Outstanding: If you are looking to replace or install a new furnace, and you are located anywhere near Stratford Ontario, you only have to make one phone call: to Dave Davies. You could spend time phoning around and getting a few estimates like I did, but you really don't need to. I was quite satisfied with three of the companies I contacted about a new furnace, but Dave Davies was a full step ahead. They offered clear and effective answers to all my questions, a thorough knowledge of all rebate programs in place, a competetive price, and fast turnaround on an expert installation. Domenic and Ken know their stuff, and did an absolutely top notch job, including little things that I was being fussy over. Dave Davies was very straightforward, offering great advice. Wilma (office admin) and Shaun (who provided the thermostat) were also very good to deal with. I would be very hard pressed to find anyone as good, let alone better.


The Outdoor Air Sensor

I dropped by Dave Davies Air Condtioning, Heating and Refrigeration to pick up the final toy to fully finish the heating system installation at the Field House: the outdoor air sensor. This little device remotely relays the outdoor temperature and humidity for display on the thermostat, as seen in the photographs below:


Close up of the display including outdoor air temperature and humidity. This is an actual shot of my unit, and not from Honeywell... I know 17.5 is a bit cool, but I was just testing the unit in Celsius!


The remote unit mounted on the exterior brick chimney wall. I didn't want to drill a new hole, so I used an existing hole which a while back had an anchor for a cable to hold tree upright.

Sunday, November 21, 2010

The New Furnace Arrives


Ken and Domenic from Dave Davies Air Conditioning Heating and Refrigeration installed a beautiful Lennox Elite Series G-61-V Two Stage variable DC fan 90,000 BTU high effieciency Energy Star rated furnace on Wednesday. Here Ken is illustrating the Ontario Workplace Health and Safety Board approved method of conducting the initial tests of the new unit, which is said to reduce lower back injuries by a significant margin. Note these newer furnaces are much more compact and closer to the ground than the older models they are replacing!



I inquired about the very fancy Honeywell Prestige thermostat, just to see if it was worth considering. It was an additional $350 on top of the furnace which had a standard thermostat included. Since I was the only one who had ever even asked about one, and Dave's son had just pulled one out of his own house in favour of a newer model that chatted with his iPhone, they provided me his at no additional charge. Sweet! I will thoroughly test this state of the art thermostat over the next few weeks, then offer my opinions.


The thermostat comes with a remote control, which allows you to access basic functions from anywhere in the house.



A close up view of the new unit, with new inlet and exhaust piping, and minor plenum modifications to fit the smaller size unit. The Space-Guard air filter was kept, as it is in essentially pristine condition, apart from some cosmetic rusting on the back of the unit.



And for the final verdict:
Total estimate price (furnace, installation, condensate pump, new inlet and exhaust, plenum mods, and basic Honeywell thermostat): $3900 + HST = $4407.
Total actual price (furnace, installation, condensate pump, new inlet and exhaust, plenum mods, relocation of furnace switch, and Honeywell Prestige thermostat): $3900 + HST = $4407.

Three other local companies provided similar estimates at $3700 (plus thermostat), $4000, and $4450, all prices plus HST. And no, even though you see high efficiency gas furnaces advertised as low as the high teens and low two thousands, those prices are inclusive of all potential rebates, and are generally for made in china single stage ac fan furnaces, which barely meet 90% AFUE standards. If you want a manufactured in North America two stage furnace, with variable speed DC motor, EnergyStar rated, the going rate is around $4000 plus HST.

Additionally, the installation qualifies for an OPG rebate of $125, a manufacturers rebate of $150, and the province's eco-energy rebates of $650 will also apply (less the net cost of $325 for the testing) so the final price will be $3807

Tuesday, November 9, 2010

Furnace Sizing: Heat Loss Calculations

Since I am of the opinion that our broken down hunk of junk furnace is grossly oversized for the heating requirements of the house, I decided to do a heat loss calculation to do things properly. The existing furnace is a 130,000 BTU 92% efficiency, which I really think is in the order of half again too big, and that something like 90,000 BTU should have no issues keeping the house warm.

I found the CMHC website which has a fantastic article on replacing a furnace, including a detailed method of doing a heat loss calculation based on your fuel bills.


The only other information needed is data on heating degree days for the period you are planning to calculate, which are available at these two sites. The first link will have you search for a local weather station, and provides historical 30 year averages for the station selected. The second link provides a Canada wide average for each of the last ten years. Specific HDD values vary by location, and you should try to get both localized data, and compare this with the Canadian data, especially if you live in places that are warmer (Victoria BC) or colder (Fort McMurray AB) than the Canadian average.



Looking at our Union Gas bill covering November 2008 through February 2009 (actual consumption from Oct 21 2008 to Feb 17 2009), I then simply cut and paste the calculation portion of the text from the CMHC site, and went through adding my own numbers below:


Total gas consumption from December to March = 2620 m3

Estimating 5% of gas is used for hot water, gas consumption during the period for heating = 2620 * 0.95 = 2490 m3

Heating degree days for that period (from Environment Canada) = 2680 HDD

Heating consumption by degree day = 2490 m3/ 2680 HDD = 0.929 m3/HDD

Heating consumption (difference of -35 coldest, from 18 ambient) at 53 HDD/day = (53 HDD/day)(0.929 m3/HDD) = 49.2 m3/day

Where gas has an energy content of 37.5 MJ/m3, and the existing furnace has an efficiency of 92 per cent, then:

Heat loss at 53 HDD/day = (49.2 m3/day) (37.5 MJ/m3)(0.92) = 1697 MJ/day or (divide by 24) 70.7 MJ/h

According to the energy content of electricity, 3.6 MJ/h = 1 kW, then 70.7 MJ/h = 19.6 kW

This heat loss would require a furnace that produces an output of 19.6 kW or about 66,900 Btu/h (1 kW is approximately 3,412 Btu/h).

If we allow the CAN/CSA F280 permissible oversizing of 40 per cent, then the proper furnace sizing would be (1.4)(20,100 Btu/h) = approximately 93700 Btu/h.


The determination of the correct furnace size for a house is NOT an exact science. Ideally the furnace size that is most efficient for any house is the size that effectivly runs close to 'flat out' only on the absolute coldest day of the year. If it is too small, it will not be able to keep the house warm enough, and if too large, it has an easy time heating during extreme cold, and becomes less efficient in mild weather.

Tuesday, October 26, 2010

The Heating System - Time to Replace The Furnace!

A while back the furnace decided to stop functioning, thankfully timing it's failure in early April, so we didn't have to run out and buy a replacement. Two of those nice oil filled radiators, a spiffy quartz heater, and a reclaimed 1500 watt convection heater did the trick to keep the house warm enough til summer arrived. Now winter is coming up, and I am making the final decision on what to install! It turns out even though the Feds canned the Eco-Energy rebate program without warning (vote conservative if you like being screwed - thanks Steve!), the Provincial government has kept their grants in place, so I have an 'Eco-Energy Audit' scheduled for this week, and next week the new furnace should go in.

Interestingly, the existing furnace is (was) a Carrier Weathermaker SX high efficiency condensing gas furnace (92% AFUE) with a whopping 122,000 BTU output. I know enough about furnaces (which is just enough) to realize that 122 k BTU is huge, and considering that even on the coldest days the beast could pull the house up from its setback of 60 deg F to 69 deg F within an hour, and then maintain that running 20 minutes every hour, it seems there was no lack of capacity!

The owner of one of the companies I contacted laughed, and said 120 thou was fine for some of the larger older homes in Stratford, like the 5 and 6 bed mansions that run 5000 square feet or more, but the Field House is 2900 sf, plus 400 sf of sunroom and mudroom, which we tend to restrict the heat to in the winter. He suggested 90,000 BTU as he has installed that size in a number of similar size and age homes with great results. The previous owners of the house left the mudroom and sunroom doors open all year, and if they heated the place to the low 'seventies, the furnace may have got the occasional solid workout!

It looks like a choice between Ida Red Apples and Ida Red Apples, as I mull over the inconsequential differences between a Ruud high efficiency (95%) two stage burner condensing gas furnace with variable speed DC blower fan motor, and a Lennox high efficiency (95%) two stage burner condensing gas furnace with variable speed DC blower fan motor, either of which will set me back around $4000, less roughly $450 in net rebates after the audit is paid for.