Tuesday, November 17, 2026

More Improvements

In the sunroom, the rough in wiring and installation has been complete, but the final insulation has to be added under Rudy's bedroom.  Temporary light fixtures have been installed before insulation and drywall is to be added, hopefully this winter.








I found these nifty battery back up, LED emergency path lights at Rona, marked down from $45 to $20... so I picked up five of them... Two are installed in the basement, with one each to be installed on the main floor, the second floor, and the attic.

This one is located on a former junction box, which looks a whole lot better now with a device mounted, rather than a blank steel cover plate. The location was perfect at the bottom of the steps to the basement.






Hard wired, interconnected smoke and CO alarms have been finally installed, two in the basement, three on the main floor, two upstairs, and one each in the attic, and yes, even the belvedere.








The last two outlets on the second floor to be wired are in Rudi's room, and are accessed from underneath via the sunroom...  Yes, I had one end of the wire dangling from the ceiling in the little used sunroom, but here are the ends now, carefully coiled up where no one can grab them... I mean, they are also not energized, so there is that, lol











 

Monday, November 16, 2026

A Covid Induced Hiatus, and more...

This summer, after close to eight years of working far too much during the pandemic, and also working far too much following the pandemic, I somehow found my motivation to get back to improving the Field House, after the better part of a decade of benign neglect.


I don't know why this box was left empty.  There are three test outlets for each of the main portion of the panel and the backup or emergency portion of the panel.  A GFCI, a regular outlet controlled by the GFCE, and an outlet with a built in switch.



And now complete, properly labelled.






Not only was toilet paper in short supply during the pandemic, so were Stab-Lok circuit breakers.  For a time I jumped a couple of low draw circuits into an extension cord... I know, I know.



But earlier this summer, I purchased additional circuit breakers, and finally installed them this fall, finishing the long,  mostly installed circuit panel for the house.







A few years ago, close to the end of the pandemic, Rudi and I re roofed the front sunroom.  Although the roof and the step flashing was long completed, I never installed counter flashing.  Thankfully, Rudy's experience as an apprentice sheet metal worker obviated the need for me to do some rudimentary flashing work myself.  Look at this incredible job on a single piece, multi step counter flashing. 










I can't believe someone did this, but they did. Probably when the house was upgraded to township water, I can't fault the previous owners for this, really.



A new freeze proof faucet spigot, installed right through the brick.






The decrepit old deck entrance on the back of the house.. My plan is to remove it entirely, and build a slightly larger walk out deck, along with a ground level deck at the bottom...



Well look at what someone hid under the shitty deck they built thirty years ago! a ton of rubble, and a cast concrete patio and set of stairs.. interesting.






Well look what I found under the sink in the kitchen! A misaligned, poorly installed, caulked drain, with unnecessary bends in the trap.



Well this is better, a new center drain, and better aligned trap... Admittedly, still an S trap, but vastly superior to the original set up.